Filtration Corporation of America
1118 Hill Avenue Glen Ellyn, IL 60137 Tel: 630.858.9030 Fax: 630.858.0953 Email:info@filtrationcorp.com Website: www.filtrationcorp.com
The VCA® (Velcon Contaminant Analyzer) uses laser sensing technology to insure that the fuel being loaded onto commercial airliners is clean and dry. In the event of wet or dirty fuel (or both), the system can act as a final stage quality check downstream of last filtration, shut down the fueling operation, and alert the user with a minimal amount of contaminated fuel reaching the plane.
VCA® Features:
Simultaneously detects and differentiates between free water and dirt in fuel.
Modular user readout, showing free water content in ppm (parts per million) and particulate solids in mg/l (milligrams per liter.)
Flow sensor operates VCA only during fueling*
Visual alarm and deadman cutoff switch in case of dirty or wet fuel
Option to tie into data management systems for automatic reporting of fueling data.
Full flow analysis.
No sampling errors.
Easy installation cable/wiring
Fully Compliant with EI 1598 Second Edition
U.S. Patent No 7,518,719
Benefits:
Completely transparent and contained operation: initiation of operation by internal flow switch and "in-situ" calibration that does not require removal for service
Ability to differentiate between water and solid particulates for proper contamination alert levels and a more efficient diagnosis of contamination source
Automatic shutdown will stop flow as soon as wet or dirty fuel is sensed
Standard Features
PC Based GUI
HAZ LOC Cert
AC-DC Voltage Converter
15 Feet (4.5m) Cable Length
Electrical Specifications
9-36 VDC, 18W
NEMA 4x enclosure w/alarm light (IP65)
Screw connect hazardous location cabling
Key switch available
Outputs
Alarm / Deadman with off signal
12 VAC, 0.8 – 1.2A – Output
Visual Alarm
Must have access to deadman control
Real-time GUI
Real-time RS-232 (8N1) Data stream, optional
Real-time data telemetry (GPRS), optional
VCA-XX Part Number Breakdown:
where XX can be any of the following:
03 – 3” (78 mm) diameter
04 – 4” (102 mm) diameter
06 – 6” (154 mm) diameter
10 - 10" (273 mm) diameter
For Explosive HAZ certification, add "EX" to the end of the model number (VCA-03EX).