Print Back
Clean Dry Fuels and Oils with High Performance

These filter housings are versatile housings designed for use with several different high performance Aquacon® and other filter cartridges.

Aquacon cartridges filter out water by chemically locking it into layers of super-absorbent media. Water capacity is as much as 11/2 quarts, depending on the specific vessel and cartridge. These cartridges also effectively filter out dirt, rust and other particulates. (See caution, back cover.)

As an Aquacon cartridge reaches its water-holding limit, the media expands very rapidly and restricts the flow. The pressure drop will rapidly increase, signaling the need to change cartridges.

The VF-61, with ACO series cartridges installed, has become the standard for low flow rate full flow aviation fuel monitor applications.
  • Wide variety of applications
  • Free and emulsified water to less than 5 ppm
  • 1/2 micron particulate removal
  • Provides protection against “slugs” of water
  • Pressure increase signals cartridge change
Over Pressure Protection
When exposed to a high concentration of water, the differential pressure across an absorbent cartridge (AC, ACO, AD, or ASL Series cartridges) will immediately increase. Pressure bypasses or other means to limit the inlet pressure to 75 psi (5 bar) should be installed to prevent cartridge from collapsing.

Notes:
  • For aviation and diesel fuel applications, always install a differential pressure gauge or other means of determing differential pressure.
  • See Data Sheet for Absorbent cartridge (AC, AD) flow rates.
  • See Data Sheet for paper filter (FO) flow rates, synthetic filter (FOS) flow rates.


Also available: VF-61UL Filter Housing, for diesel fuels. Recognized under the Component Recognition Program of Underwriters Laboratories Inc.
Unit of Measure

Specifications

Cover

N/A Bolted, 4 bolts

Inlet/Outlet Connection

N/A 1 1/2" NPT

Max. Operating Pressure

N/A 150 psi

Weight

N/A 8 lbs

Shipping Weight

N/A 10 lbs

Material

N/A Cast aluminum head, carbon steel shell with epoxy powder coated exterior & interior

Product being filtered

N/A Diesel Jet Fuel & Avgas Mo-gas Oils Solvents

Options

N/A P/N 10678 - (Differential pressure gauge assembly)
P/N 554Y020 - (Carbon steel 1/2" NPT ball valve, with mounting nipple)
P/N CK-1488 (Quick release hand bolts)

Recommended Spares

N/A 1 ea P/N G-0986 Buna-N O-ring 2 ea P/N G-0986A Viton O-rings (If using with gasoline/solvent applications) 6 ea replacement filter cartridges

Accessories

Supplied with

N/A
  • 1 ea P/N G-0986 Buna-N O-ring
  • 1/8” brass petcock vent valve, installed
  • 1/2” drain plug, installed
  • 1 ea 1/2” petcock drain, shipped loose

Applications

N/A

  • Jet Fuel
  • Avgas
  • Motor Gasoline
  • Diesel Fuel
  • Biodiesel
  • Selected Solvents Oils: Insulating, Hydraulic, Lubricating Compressed Air and Other Gasses

Caution

N/A To protect the fuel system, including the VF-609 and other components, be sure to install pressure relief valve(s).

Do not use absorbent cartridges (ACO-xxxxxL, AC-xxxxx, AD-xxxxx) with pre-mixed jet fuel or avgas containing anti-icing additives.